Create a profile that matches the declared controller and receiver boundary. The profile defines evaluation inputs. It must not be treated as an authorization to control a physical system.

Minimal template

{
  "schema_version": "1.0",
  "profile_id": "my_robot_v0",
  "applicable_standards": ["ISO 3691-4:2023"],
  "producer_config": {
    "name": "my_navigation_stack",
    "interface_type": "ros2_diff_drive",
    "command_rate_hz": 10.0,
    "sequence_policy": {
      "sequence_rollover": "monotonic_64",
      "stale_data_age_ms": 500.0,
      "reset_epoch": "controller_start",
      "queue_overflow_behavior": "drop_oldest",
      "invalid_numeric_behavior": "reject"
    }
  },
  "receiver_config": {
    "name": "my_motion_controller",
    "controller_type": "motion_controller",
    "max_latency_deadline_ms": 100.0,
    "safety_function_class": "SIL2"
  },
  "command_limits": {
    "max_linear_velocity_mps": 1.5,
    "max_angular_velocity_rads": 1.0
  },
  "fault_corpus": {
    "faults": [
      {"fault_id": "fc_001_stale", "kind": "stale_command", "description": "Command gap exceeds stale threshold", "expected_state": "safe_halt"}
    ]
  }
}

Evaluate the declared profile

argus regression-eval --trace your_trace.json --profile my_robot_v0.json --out out/my-evaluation

The safety_function_class field is an input label. It does not create an SIL or ASIL claim, nor does it replace a product-specific safety programme.